EVSE - Status
EVSE - Status — Reads status information from the
EVSE board.
Library
Simulink Real-Time - Speedgoat

Description
The EVSE Status block reads status information from the EVSE charging board during
the charge cycle and outputs the data to Simulink.
Ports
Outputs
-
Charging State
The charge state the EVSE charging board is currently in.
Data Type: double
-
Protocol
The charging protocol in use in the current charge cycle. Possible
values are:
"ISO 15118"
"DIN 70121"
"IEC 61851"
"NotSupported"
Data Type: string
-
CP
Indicates the current Control Pilot (CP) state. The possible values of
this topic are the CP states according to IEC 61851:
1: State A - EV unplugged
2: State B - EV connected
3: State C - Ready / Charging
4: State D - With ventilation
5: State E - Power outage or short of the control pilot to
PE
6: State F - Error - unavailability of the charging
station
Data Type: double
-
PP
Indicates the current Proximity Pilot (PP) state. The possible values
of this topic are the PP states according to IEC 61851:
Data Type: double
-
PWM
Indicates the current PWM duty cycle in percent. The value of this
topic is between "0" and "100" %.
Data Type: double
-
TCP
Indicates the status of the TCP connection between the EV and the
EVSE. The possible values of this topic are:
Data Type: double
-
Plug
Indicates the status of the plug lock on the customer side. The
possible values of this topic are:
0: unlocked
1: locked
2: unknown
Data Type: double
Parameters
-
Station ID
Defines the Station ID of the corresponding Setup block. Must range
between 0 and 65535.
-
Connection ID
Defines the Connection ID of the corresponding Setup block. Must range
between 0 and 65535.
-
Sample Time
Defines the base sample time at which this driver block gets its
sample hit. This parameter can also be set to -1 for inherited sample time. The units are in
seconds.