Documentation search search close
CONTENTS
https://www.speedgoat.com/help/slrt/page/icon_documentation.jpg
v10.0.1.x for R2026a
View other versions

EV - Pre-Charge Read

EV - Pre-Charge Read — Reads data from the EV board during the Pre-Charge state of the charge cycle.

Library

Simulink Real-Time - Speedgoat

Description

The EV Pre-Charge Read block reads data from the EV charging board during the Pre-Charge state of the charge cycle.

Ports

Outputs
EVSE Isolationstatus

The chargers isolation status communicated by the EVSE, following enumeration table "isolationLevelType" of ISO 15118-2.

  • 0: Invalid

  • 1: Valid

  • 2: Warning

  • 3: Fault

  • 4: No isolation monitoring device (IMD) present

EVSE Statuscode

The charger's statuscode communicated by the EVSE, following enumeration table "DC_EVSEStatusCodeType" of ISO 15118-2.

  • 0: Not Ready

  • 1: Ready

  • 2: Shutdown

  • 3: Utility interrupt event

  • 4: Isolation monitoring active

  • 5: Emergency shutdown

  • 6: Malfunction

EVSE Present Voltage

The charger's present voltage communicated to the EV.

Parameters

Station ID

Defines the Station ID of the corresponding Setup block. Must range between 0 and 65535.

Connection ID

Defines the Connection ID of the corresponding Setup block. Must range between 0 and 65535.

Sample Time

Defines the base sample time at which this driver block gets its sample hit. This parameter can also be set to -1 for inherited sample time. The units are in seconds.