EVSE - Isolation Write
EVSE - Isolation Write — Writes data to the EVSE
board during the Isolation state of the charge cycle.
Library
Simulink Real-Time - Speedgoat

Description
The EVSE Isolation Write block writes data to the EVSE charging board during the
Isolation state of the charge cycle.
Ports
Inputs
-
EVSE Processing
This enumeration signal provides the processing status of the charger,
following the enumeration table "EVSEProcessingType" of ISO 15118-2:
-
Isolationstatus
Set the charger's isolation status following enumeration table
"isolationLevelType" of ISO 15118-2.
-
Statuscode
Set the charger's status following enumeration table
"DC_EVSEStatusCodeType" of ISO 15118-2.
Parameters
Main Tab
-
Station ID
Defines the Station ID of the corresponding Setup block. Must range
between 0 and 65535.
-
Connection ID
Defines the Connection ID of the corresponding Setup block. Must range
between 0 and 65535.
-
Sample Time
Defines the base sample time at which this driver block gets its
sample hit. This parameter can also be set to -1 for inherited sample time. The units are in
seconds.
Enable/Disable Signals Tab
Some settings, like min. and max. voltage limits, are already set by the Setup
block but can be overwritten during the Parameter Discovery state of the charge
if desired. However, unused signals that remain unconnected are set to zero. To
avoid setting parameters to zero, unused signals should be unchecked here to
disable the write operation.
The following signals can be disabled: