Documentation search search close
CONTENTS
https://www.speedgoat.com/help/slrt/page/icon_documentation.jpg
v10.0.1.x for R2026a
View other versions

EV - Welding Read

EV - Welding Read — Reads data from the EV board during the Welding state of the charge cycle.

Library

Simulink Real-Time - Speedgoat

Description

The EV Welding Read block reads data from the EV charging board during the Welding state of the charge cycle.

Ports

Outputs
EVSE Notification

Enumerated notification issued by the EVSE, following enumeration table "EVSENotificationType" of ISO 15118-2.

  • 0: None

  • 1: Stop charging

  • 2: Renegotiation

EVSE Isolationstatus

The chargers isolation status communicated by the EVSE, following enumeration table "isolationLevelType" of ISO 15118-2.

  • 0: Invalid

  • 1: Valid

  • 2: Warning

  • 3: Fault

  • 4: No isolation monitoring device (IMD) present

EVSE Statuscode

The charger's statuscode communicated by the EVSE, following enumeration table "DC_EVSEStatusCodeType" of ISO 15118-2.

  • 0: Not Ready

  • 1: Ready

  • 2: Shutdown

  • 3: Utility interrupt event

  • 4: Isolation monitoring active

  • 5: Emergency shutdown

  • 6: Malfunction

EVSE Present Voltage

The charger's present voltage communicated to the EV.

Parameters

Station ID

Defines the Station ID of the corresponding Setup block. Must range between 0 and 65535.

Connection ID

Defines the Connection ID of the corresponding Setup block. Must range between 0 and 65535.

Sample Time

Defines the base sample time at which this driver block gets its sample hit. This parameter can also be set to -1 for inherited sample time. The units are in seconds.