EV - Isolation Read

EV - Isolation Read — Reads data from the EV board during the Isolation state of the charge cycle.

Library

Simulink Real-Time - Speedgoat

Description

The EV Isolation Read block reads data from the EV charging board during the Isolation state of the charge cycle.

Ports

Outputs
EVSE Processing

This enumeration signal provides the processing status of the charger, following the enumeration table "EVSEProcessingType" of ISO 15118-2:

  • 0: Finished

  • 1: Ongoing

  • 2: Ongoing, waiting for customer interaction

EVSE Isolationstatus

The chargers isolation status communicated by the EVSE, following enumeration table "isolationLevelType" of ISO 15118-2.

  • 0: Invalid

  • 1: Valid

  • 2: Warning

  • 3: Fault

  • 4: No isolation monitoring device (IMD) present

EVSE Statuscode

The charger's statuscode communicated by the EVSE, following enumeration table "DC_EVSEStatusCodeType" of ISO 15118-2.

  • 0: Not Ready

  • 1: Ready

  • 2: Shutdown

  • 3: Utility interrupt event

  • 4: Isolation monitoring active

  • 5: Emergency shutdown

  • 6: Malfunction

Parameters

Station ID

Defines the Station ID of the corresponding Setup block. Must range between 0 and 65535.

Connection ID

Defines the Connection ID of the corresponding Setup block. Must range between 0 and 65535.

Sample Time

Defines the base sample time at which this driver block gets its sample hit. This parameter can also be set to -1 for inherited sample time. The units are in seconds.