Documentation search search close
CONTENTS
https://www.speedgoat.com/help/slrt/page/icon_documentation.jpg
v10.0.1.x for R2026a
View other versions

EVSE - Parameter Read

EVSE - Parameter Read — Reads data from the EVSE board during the Parameter Discovery state of the charge cycle.

Library

Simulink Real-Time - Speedgoat

Description

The EVSE Parameter Read block reads data from the EVSE charging board during the Parameter Discovery state of the charge cycle.

Ports

Outputs
EV Requested Energy Type

The energy type requested by the connected EV. Following enumeration table "energyTransferType" ISO 15118-2:

  • 0: AC_single_phase_core

  • 1: AC_three_phase_core

  • 2: DC_core

  • 3: DC_extended

  • 4: DC_combo_core

  • 5: DC_unique

EV Departure Time

The departure time communicated by the EV in seconds from now.

EV Max Voltage Limit

The maximum voltage limit of the EV in volts.

EV Max Current Limit

The maximum current limit of the EV in amperes.

EV Min Current Limit

The minimum current limit of the EV in amperes.

EV Max Power Limit

The maximum power limit of the EV in watts.

EV Ready

Indicates if the EV is ready to charge generally.

  • 0: not ready

  • 1: ready

EV Errorcode

Errorcode following enumeration table "DC_EVErrorCodeType" ISO 15118-2:

  • 0: EV_NO_ERROR

  • 1: EV_FAILED_RESS_TEMPERATURE_INHIBIT

  • 2: EV_FAILED_EV_SHIFT_POSITION

  • 3: EV_FAILED_CHARGER_CONNECTOR_LOCK_FAULT

  • 4: EV_FAILED_EVRESS_MALFUNCTION

  • 5: EV_FAILED_CHARGING_CURRENTDIFFERENTIAL

  • 6: EV_FAILED_CHARGING_VOLTAGE_OUT_OF_RANGE

  • 7: EV_RESERVED_A

  • 8: EV_RESERVED_B

  • 9: EV_RESERVED_C

  • 10: EV_FAILED_CHARGING_SYSTEM_INCOMPATIBILITY

  • 11: EV_NO_DATA

EV RESS SOC

Current state of charge (SoC) of the EV's rechargeable energy storage system (RESS).

EV Energy Capacity

Energy capacity of the EV in watt-hours.

EV Energy Request

Energy requested by the EV in watt-hours.

EV Full SOC

State of charge (SoC), in percentage, that the EV considers fully charged. Typically 100.

EV Bulk SOC

State of charge (SoC), in percentage, at which the EV's bulk charge is complete. Typically 80.

Parameters

Station ID

Defines the Station ID of the corresponding Setup block. Must range between 0 and 65535.

Connection ID

Defines the Connection ID of the corresponding Setup block. Must range between 0 and 65535.

Sample Time

Defines the base sample time at which this driver block gets its sample hit. This parameter can also be set to -1 for inherited sample time. The units are in seconds.