EVSE - Pre-Charge Read
EVSE - Pre-Charge Read — Reads data from the EVSE
board during the Pre-Charge state of the charge cycle.
Library
Simulink Real-Time - Speedgoat

Description
The EVSE Pre-Charge Read block reads data from the EVSE charging board during the
Pre-Charge state of the charge cycle.
Ports
Outputs
-
EV Ready
Indicates if the EV is ready to charge generally.
-
EV Errorcode
Errorcode following enumeration table "DC_EVErrorCodeType" ISO
15118-2:
0: EV_NO_ERROR
1: EV_FAILED_RESS_TEMPERATURE_INHIBIT
2: EV_FAILED_EV_SHIFT_POSITION
3: EV_FAILED_CHARGER_CONNECTOR_LOCK_FAULT
4: EV_FAILED_EVRESS_MALFUNCTION
5: EV_FAILED_CHARGING_CURRENTDIFFERENTIAL
6: EV_FAILED_CHARGING_VOLTAGE_OUT_OF_RANGE
7: EV_RESERVED_A
8: EV_RESERVED_B
9: EV_RESERVED_C
10: EV_FAILED_CHARGING_SYSTEM_INCOMPATIBILITY
11: EV_NO_DATA
-
EV RESS SOC
Current state of charge (SoC) of the EV's rechargeable energy storage
system (RESS).
-
EV Target Voltage
The target voltage requested by the EV in volts.
-
EV Target Current
The target current requested by the EV in amperes.
Parameters
-
Station ID
Defines the Station ID of the corresponding Setup block. Must range
between 0 and 65535.
-
Connection ID
Defines the Connection ID of the corresponding Setup block. Must range
between 0 and 65535.
-
Sample Time
Defines the base sample time at which this driver block gets its
sample hit. This parameter can also be set to -1 for inherited sample time. The units are in
seconds.