IO601 - LIN Status v2
IO601 - LIN Status v2 — This block is used to read
status information from the LIN channel
Library
Simulink Real-Time - Speedgoat

Description
This block can be used to get the current status of a LIN channel. The link to the
corresponding LIN module can be set in the block mask. The status information is
updated every 128ms by the LIN controller on the IO601 module.
Ports
Outputs
-
Role
LIN operating mode:
Data
Type:uint32
-
Bus load
Bus load in [%]. Data
Type:uint32
-
Baud rate
The currently configured baud rate in [bits/s]. Data Type:uint32
-
Status
LIN status:
Data
Type:uint32
Parameters
-
Module ID
This ID defines the link to the corresponding Setup block
-
Sample Time
Defines the base sample time at which this driver block gets its sample hit. This
parameter can also be set to -1 for inherited
sample time. The units are in seconds.
- Enable Role
Enables the output port for role information.
- Enable Busload
Enables the output port for busload information.
- Enable Baud rate
Enables the output port for baud rate information.
- Enable Status
Enables the output port for status information.