IO601 - CAN Setup v4

IO601 - CAN Setup v4 — Configure the IO601 CAN interface

Library

Simulink Real-Time - Speedgoat

Description

Your model must contain one "CAN Setup" driver block for each IO601 module in your target machine. This block allows all of the supported I/O types of this module to be configured and therefore impacts on the other driver blocks (CAN Write, CAN Read, and CAN Status).

Ports

This driver block has no input or output ports.

Parameters

Module setup
Module ID

The Module ID has two functions:

  • It defines the logical connection between the Setup block and its I/O blocks

  • It also informs the auto-search feature of the PCI Slot parameter. If only one I/O module of this type is installed, the Module ID must be set to 1. If n modules are installed, it must be in the range 1:n. Not all the I/O modules installed in the target machine need to be used. To see how each I/O module maps to a Module ID, use this Speedgoat API:

    speedgoat.getIoInterfaces("TargetName", "mySpeedgoat")
Init structure

Defines CAN messages sent during initialization of the Write block. For more information, see: Initialization and Termination CAN Messages.

Term structure

Defines CAN messages sent during termination of the Write block. For more information, see: Initialization and Termination CAN Messages.

PCI Slot (-1: auto-search)

There are two approaches for mapping this block to a specific I/O module installed in your target machine. All modules of the same type must be configured using the same method.

  • Auto-Search: with the default value -1 the I/O module will be automatically located in the target machine. If you have multiple modules of the same kind, the Module ID defines which module is associated with this block. To see how each I/O module maps to a Module ID, use this Speedgoat API:

    speedgoat.getIoInterfaces("TargetName", "mySpeedgoat")

  • Explicit Addressing: to explicitly define the logical address of the I/O module in the target machine, you can provide the PCI bus and slot numbers as a vector: [bus, slot]. To determine these numbers, run the following command in the MATLAB command window:

    speedgoat.getIoInterfaces("TargetName", "mySpeedgoat", "Advanced", true)

    Note that the PCI address can change whenever an I/O module is added or removed – usually, auto-search is the best option.

CAN Channel 1
Enable

When enabled, the CAN 1 channel is initialized at target application download time. By default the box is checked. If unchecked, it is assumed that the model does not contain a Write block to transmit to the CAN 1 channel, or a Read block to receive from the CAN 1 channel.

Physical bus

The transceiver mode for this CAN channel. The options are:

  • Highspeed (default)

  • Lowspeed

Baud rate

The baud rate for this CAN channel. This control allows the most commonly used values to be selected. If special bit timing is needed, then select the User defined here and use the "User defined baud rate" parameter below.

User defined baud rate

If "User defined" has been selected in the "Baud rate" parameter above, this parameter is used to configure the bit timing. The parameter is a vector with the following elements:

  • Prescaler (BRP)

  • Synchronization-Jump-Width (SJW)

  • Time-Segment-1 (TSEG1)

  • Time-Segment-2 (TSEG2)

For information concerning the IO601 bit-timing values, please contact technical support (support@speedgoat.com) to obtain the "IO601_bit_timing.pdf" manual.

Acceptance (standard identifier)

The rule to decide whether a CAN message with a standard ID (11 bits) is accepted on CAN channel 1. The message is accepted if either of the following rules is true:

  • ((ID & StdMask1) == StdCode1)

  • ((ID & StdMask2) == StdCode2)

Set a StdMask element to zero (the default) to disable a rule. Note that this parameter takes a decimal value. See the "Usage notes" section for examples of how to set this parameter.

Acceptance (extended identifier)

The rule to decide whether a CAN message with an extended ID (29 bits) is accepted on CAN channel 1. The message is accepted if either of the following rules is true:

  • ((ID & ExtMask1) == ExtCode1)

  • ((ID & ExtMask2) == ExtCode2)

Set an ExtMask element to zero (the default) to disable a rule. Note that this parameter takes a decimal value. See the "Usage notes" section for examples of how to set this parameter.

CAN Channel 2
Enable

When enabled, the CAN 2 channel is initialized at target application download time. By default the box is checked. If unchecked, it is assumed that the model does not contain a Write block which transmits to CAN 2 channel, or a Read block which receives from CAN 2 channel.

Physical bus

The transceiver mode for this CAN channel. The options are:

  • Highspeed (default)

  • Lowspeed

Baud rate

The baud rate for this CAN channel. This control allows the most commonly used values to be selected. If special bit timing is needed, then select the User defined here and use the "User defined baud rate" parameter below.

User defined baud rate

If "User defined" has been selected in the "Baud rate" parameter above, this parameter is used to configure the bit timing. The parameter is a vector with the following elements:

  • Prescaler (BRP)

  • Synchronization-Jump-Width (SJW)

  • Time-Segment-1 (TSEG1)

  • Time-Segment-2 (TSEG2)

For information concerning the IO601 bit-timing values, please contact technical support (support@speedgoat.com) to obtain the "IO601_bit_timing.pdf" manual.

Acceptance (standard identifier)

The rule to decide whether a CAN message with a standard ID is accepted on CAN channel 2. The message is accepted if either of the following rules is true:

  • ((ID & StdMask1) == StdCode1)

  • ((ID & StdMask2) == StdCode2)

Set a StdMask element to zero (the default) to disable a rule.

Acceptance (extended identifier)

The rule to decide whether a CAN message with an extended ID is accepted on CAN channel 2. The message is accepted if either of the following rules is true:

  • ((ID & ExtMask1) == ExtCode1)

  • ((ID & ExtMask2) == ExtCode2)

Set an ExtMask element to zero (the default) to disable a rule.

LIN Channel 1
Role

The IO601 can be configured to act as a master or a slave. In the LIN topology, only one master is allowed per network.

Baud rate

This parameter is valid for master and slave operation. Range between 2400 and 20000.

LIN v2.x (enhanced check sum)

When enabled, the IO601 will use the enhanced check sum as defined in the LIN 2.0 (and newer) specification. Otherwise, the classic check sum (up to LIN 1.3) is applied.