Serial - Read HW FIFO v1

Serial - Read HW FIFO v1 — The Serial Read HW FIFO driver block allows data to be read from an Serial Transceiver

Library

Simulink Real-Time - Speedgoat

Description

The Serial Read HW FIFO v1 driver block can read up to 256 bytes of data present in the I/O module hardware buffer.

Ports

Inputs
enable

A global switch which enables (1) or disables (0) the read operation.

Outputs
data

A vector of 129 elements which represents the Serial HW FIFO. First element of this vector indicates how many bytes have been read from the FIFO. Subsequent elements form the data.

Parameters

Configurable I/O Module ID

This parameter associates a code module block with a configurable I/O module setup block. Set this value to match the Module ID defined in the setup block of the required configurable I/O module.

Channel Vector

A vector of channels this driver block entity will access. You can specify channels in the range 1-N (N = the number of channels implemented in your specific configuration file defined in the Setup block). The width of this vector also defines the subsequent size of some of the following parameters if scalar expansion applies. With a single block, all the channels of the block are synchronized.

Sample Time

Defines the base sample time at which this driver block gets its sample hit. This parameter can also be set to -1 for inherited sample time. The units are in seconds.