Enable Tx Termination Resistor
Terminate Tx line with a 120Ω termination resistor (this setting is
ignored in RS232 mode).
-
Enable Rx Termination Resistor
Terminate Rx line with a 120Ω termination resistor (this setting is
ignored in RS232 mode).
-
Enable Tx Message Monitoring
This checkbox can be used to enable/disable the reception of an echo
of the own data transmission in the RS485 Half-Duplex mode.
-
Auto Turn Around
The auto turn around is enabled per default for the RS485 Half-Duplex
mode. In the RS485 Full-Duplex mode it can be enabled if required. In
the RS485 mode, where the transmitters and receivers use the same
differential pair of wires, you can only enable one transmitter at a
time. Therefore the RTS output is routed to the enable input of the
RS485 transmitter.
-
Turn Around Delay
The UART automatically asserts RTS when there are characters in the
transmit FIFO. It de-asserts RTS when the transmit FIFO empties and the
RS485 turnaround default delay of 0 to 15 bit time periods elapses. The
transmitter output goes tristate (high impedance) when disabled, which
allows another device to transmit.
-
Use Standard Baud Rates (16x, no prescaling)
Check this box if you want to use a standard baud rate
-
Standard Baud Rate
Select the baud rate from a list of standard baud rates
-
Baud Rate Divisor
The non-standard baud rate is determined by the following formula:

The prescaler can be set using the Prescaler parameter. The prescaler default is "None"
which equals to "x1". The sampling rate can be either 8 or 16. The
divisor must fall withing range of 1 - 65535. Note that the divisor must
be an integer for the I/O modules IO503,IO504 and IO505.
-
Sampling Rate
The sampling rate can be set to 8x or 16x (normal operation). Transmit
and receive data rates will double by selecting 8x sample rate.
-
Prescaler
Sets the Prescale value used to calculate a non-standard baud rate.
"None" means the prescaler equals times one (1x). Selecting the 4x from
the dropdown list sets it to times four.
- Baud Rate
If non-standard baud rate mode is selected, this field shows the
calculated baud rate using the parameters from above and the respective
oscillator frequency of the module.
-
Parity
Parity is a method for detecting errors during transmission. Options
are:
-
Data Bits
The number of data bits for each character. Options are: 5, 6, 7 or 8.
-
Stop Bits
The number of stop bits sent at the end of every character. Options
are: 1 or 2.
-
Transmit FIFO Interrupt Level
This parameter specifies the number of characters left in the transmit
FIFO before an interrupt occurs.
-
Receive FIFO Interrupt Level
This parameter specifies the number of characters in the receive FIFO
before an interrupt occurs. Receive interrupts occur at least as often
as this parameter specifies. If a gap of at least 4 character periods
occurs in a data stream, the UART requests an interrupt for the
receiver.
-
Handshake
Select if hardware or software handshake should be used. Flow control
is used to prevent data overrun to the local receiver FIFO and remote
receiver FIFO. Hardware handshake can only be used in RS232 mode. If
software flow control is selected, the XOFF character is transmitted
approximately two character time periods after the RX FIFO level has
reached the RX trigger level. The XON character is transmitted when the
RX FIFO level falls below the RX trigger level. If RTS Hysteresis is not
0, the XON character gets transmitted when the RX FIFO level falls below
the RX trigger level minus the selected hysteresis. The following modes
are available for flow control:
RTS/CTS: Use the RTS/CTS pins for flow control
Tx XON/XOFF: Only transmit flow control characters
Rx XON/XOFF: Only receive flow control characters
Tx/Rx XON/XOFF: Transmit and receive flow control
characters
- RTS Hysteresis
Select the amount of characters at which RTS should be de/re-asserted.
Transmission is re-asserted if the RX FIFO level is below the RX FIFO
trigger level minus the selected hysteresis. It de-asserts if the RX
FIFO level is above the RX FIFO trigger level plus the selected
hysteresis.
-
XON Character
This parameter defines the XON character. If two characters are
specified they are concatenated into two sequential characters.
-
XOFF Character
This parameter defines the XOFF character. If two characters are
specified they are concatenated into two sequential characters.
-
Transmit Software FIFO Size
The size of the software FIFO used to buffer transmitted characters.
For each I/O module, a minimum buffer size must be set. Refer to the
serial usage notes
for more information about the FIFO buffer sizes. This parameter also
defines the input port width of the corresponding write block.
-
Receive Software FIFO Size
The size of the software FIFO to buffer characters between interrupt
service and periodic execution. For each I/O module, a minimum buffer
size must be set. Refer to the serial usage notes
for more information about the FIFO buffer sizes. This parameter also
defines the output port width of the corresponding read block.