Documentation search search close
CONTENTS
https://www.speedgoat.com/help/slrt/page/icon_documentation.jpg
v10.0.1.x for R2026a
View other versions

OPC UA Status Codes

OPC UA Status Codes — Reference information about the OPC UA status codes

Status Codes for the OPC UA communication protocol

The table below lists the codes the OPC UA driver blocks output in the system log in the event of errors.

CodeDescription
0x00000000The operation succeeded
0x40000000The operation was uncertain
0x80000000The operation failed
0x80010000An unexpected error occurred
0x80020000An internal error occurred as a result of a programming or configuration error
0x80030000Not enough memory to complete the operation
0x80040000An operating system resource is not available
0x80050000A low level communication error occurred
0x80060000Encoding halted because of invalid data in the objects being serialized
0x80070000Decoding halted because of invalid data in the stream
0x80080000The message encoding/decoding limits imposed by the stack have been exceeded
0x80B80000The request message size exceeds limits set by the server
0x80B90000The response message size exceeds limits set by the client
0x80090000An unrecognized response was received from the server
0x800A0000The operation timed out
0x800B0000The server does not support the requested service
0x800C0000The operation was cancelled because the application is shutting down
0x800D0000The operation could not complete because the client is not connected to the server
0x800E0000The server has stopped and cannot process any requests
0x800F0000There was nothing to do because the client passed a list of operations with no elements
0x80100000The request could not be processed because it specified too many operations
0x80DB0000The request could not be processed because there are too many monitored items in the subscription
0x80110000The extension object cannot be (de)serialized because the data type id is not recognized
0x80120000The certificate provided as a parameter is not valid
0x80130000An error occurred verifying security
0x81140000The certificate does not meet the requirements of the security policy
0x80140000The certificate has expired or is not yet valid
0x80150000An issuer certificate has expired or is not yet valid
0x80160000The HostName used to connect to a server does not match a HostName in the certificate
0x80170000The URI specified in the ApplicationDescription does not match the URI in the certificate
0x80180000The certificate may not be used for the requested operation
0x80190000The issuer certificate may not be used for the requested operation
0x801A0000The certificate is not trusted
0x801B0000It was not possible to determine if the certificate has been revoked
0x801C0000It was not possible to determine if the issuer certificate has been revoked
0x801D0000The certificate has been revoked
0x801E0000The issuer certificate has been revoked
0x810D0000The certificate chain is incomplete
0x801F0000User does not have permission to perform the requested operation
0x80200000The user identity token is not valid
0x80210000The user identity token is valid but the server has rejected it
0x80220000The specified secure channel is no longer valid
0x80230000The timestamp is outside the range allowed by the server
0x80240000The nonce does appear to be not a random value or it is not the correct length
0x80250000The session id is not valid
0x80260000The session was closed by the client
0x80270000The session cannot be used because ActivateSession has not been called
0x80280000The subscription id is not valid
0x802A0000The header for the request is missing or invalid
0x802B0000The timestamps to return parameter is invalid
0x802C0000The request was cancelled by the client
0x80E50000Too many arguments were provided
0x810E0000The server requires a license to operate in general or to perform a service or operation
0x810F0000The server has limits on number of allowed operations / objects
0x81100000The server does not have a license which is required to operate in general or to perform a service or operation
0x002D0000The subscription was transferred to another session
0x002E0000The processing will complete asynchronously
0x002F0000Sampling has slowed down due to resource limitations
0x00300000The value written was accepted but was clamped
0x80310000Communication with the data source is defined
0x80320000Waiting for the server to obtain values from the underlying data source
0x80330000The syntax of the node id is not valid
0x80340000The node id refers to a node that does not exist in the server address space
0x80350000The attribute is not supported for the specified Node
0x80360000The syntax of the index range parameter is invalid
0x80370000No data exists within the range of indexes specified
0x80380000The data encoding is invalid
0x80390000The server does not support the requested data encoding for the node
0x803A0000The access level does not allow reading or subscribing to the Node
0x803B0000The access level does not allow writing to the Node
0x803C0000The value was out of range
0x803D0000The requested operation is not supported
0x803E0000A requested item was not found or a search operation ended without success
0x803F0000The object cannot be used because it has been deleted
0x80400000Requested operation is not implemented
0x80410000The monitoring mode is invalid
0x80420000The monitoring item id does not refer to a valid monitored item
0x80430000The monitored item filter parameter is not valid
0x80440000The server does not support the requested monitored item filter
0x80450000A monitoring filter cannot be used in combination with the attribute specified
0x80460000A mandatory structured parameter was missing or null
0x80470000The event filter is not valid
0x80480000The content filter is not valid
0x80C10000An unrecognized operator was provided in a filter
0x80C20000A valid operator was provided
0x80C30000The number of operands provided for the filter operator was less then expected for the operand provided
0x80490000The operand used in a content filter is not valid
0x80C40000The referenced element is not a valid element in the content filter
0x80C50000The referenced literal is not a valid value
0x804A0000The continuation point provide is longer valid
0x804B0000The operation could not be processed because all continuation points have been allocated
0x804C0000The reference type id does not refer to a valid reference type node
0x804D0000The browse direction is not valid
0x804E0000The node is not part of the view
0x81120000The number was not accepted because of a numeric overflow
0x804F0000The ServerUri is not a valid URI
0x80500000No ServerName was specified
0x80510000No DiscoveryUrl was specified
0x80520000The semaphore file specified by the client is not valid
0x80530000The security token request type is not valid
0x80540000The security mode does not meet the requirements set by the server
0x80550000The security policy does not meet the requirements set by the server
0x80560000The server has reached its maximum number of sessions
0x80570000The user token signature is missing or invalid
0x80580000The signature generated with the client certificate is missing or invalid
0x80590000The client did not provide at least one software certificate that is valid and meets the profile requirements for the server
0x80C60000The server does not support changing the user identity assigned to the session
0x805A0000The request was cancelled by the client with the Cancel service
0x805B0000The parent node id does not to refer to a valid node
0x805C0000The reference could not be created because it violates constraints imposed by the data model
0x805D0000The requested node id was reject because it was either invalid or server does not allow node ids to be specified by the client
0x805E0000The requested node id is already used by another node
0x805F0000The node class is not valid
0x80600000The browse name is invalid
0x80610000The browse name is not unique among nodes that share the same relationship with the parent
0x80620000The node attributes are not valid for the node class
0x80630000The type definition node id does not reference an appropriate type node
0x80640000The source node id does not reference a valid node
0x80650000The target node id does not reference a valid node
0x80660000The reference type between the nodes is already defined
0x80670000The server does not allow this type of self reference on this node
0x80680000The reference type is not valid for a reference to a remote server
0x80690000The server will not allow the node to be deleted
0x40BC0000The server was not able to delete all target references
0x806A0000The server index is not valid
0x806B0000The view id does not refer to a valid view node
0x80C90000The view timestamp is not available or not supported
0x80CA0000The view parameters are not consistent with each other
0x80CB0000The view version is not available or not supported
0x40C00000The list of references may not be complete because the underlying system is not available
0x00BA0000The server should have followed a reference to a node in a remote server but did not The result set may be incomplete
0x80C80000The provided Nodeid was not a type definition nodeid
0x406C0000One of the references to follow in the relative path references to a node in the address space in another server
0x806D0000The requested operation has too many matches to return
0x806E0000The requested operation requires too many resources in the server
0x806F0000The requested operation has no match to return
0x80700000The max age parameter is invalid
0x80E60000The operation is not permitted over the current secure channel
0x80710000The history details parameter is not valid
0x80720000The server does not support the requested operation
0x80BD0000The defined timestamp to return was invalid
0x80730000The server does not support writing the combination of value
0x80740000The value supplied for the attribute is not of the same type as the attribute's value
0x80750000The method id does not refer to a method for the specified object
0x80760000The client did not specify all of the input arguments for the method
0x81110000The executable attribute does not allow the execution of the method
0x80770000The server has reached its maximum number of subscriptions
0x80780000The server has reached the maximum number of queued publish requests
0x80790000There is no subscription available for this session
0x807A0000The sequence number is unknown to the server
0x00DF0000The Server does not support retransmission queue and acknowledgement of sequence numbers is not available
0x807B0000The requested notification message is no longer available
0x807C0000The client of the current session does not support one or more Profiles that are necessary for the subscription
0x80BF0000The sub-state machine is not currently active
0x81150000An equivalent rule already exists
0x807D0000The server cannot process the request because it is too busy
0x807E0000The type of the message specified in the header invalid
0x807F0000The SecureChannelId and/or TokenId are not currently in use
0x80800000The size of the message chunk specified in the header is too large
0x80810000There are not enough resources to process the request
0x80820000An internal error occurred
0x80830000The server does not recognize the QueryString specified
0x80840000The request could not be sent because of a network interruption
0x80850000Timeout occurred while processing the request
0x80860000The secure channel has been closed
0x80870000The token has expired or is not recognized
0x80880000The sequence number is not valid
0x80BE0000The applications do not have compatible protocol versions
0x80890000There is a problem with the configuration that affects the usefulness of the value
0x808A0000The variable should receive its value from another variable
0x808B0000There has been a failure in the device/data source that generates the value that has affected the value
0x808C0000There has been a failure in the sensor from which the value is derived by the device/data source
0x808D0000The source of the data is not operational
0x808E0000The deadband filter is not valid
0x408F0000Communication to the data source has failed The variable value is the last value that had a good quality
0x40900000Whatever was updating this value has stopped doing so
0x40910000The value is an operational value that was manually overwritten
0x40920000The value is an initial value for a variable that normally receives its value from another variable
0x40930000The value is at one of the sensor limits
0x40940000The value is outside of the range of values defined for this parameter
0x40950000The value is derived from multiple sources and has less than the required number of Good sources
0x00960000The value has been overridden
0x80970000This Condition refresh failed
0x80980000This condition has already been disabled
0x80CC0000This condition has already been enabled
0x80990000Property not available
0x809A0000The specified event id is not recognized
0x80BB0000The event cannot be acknowledged
0x80CD0000The dialog condition is not active
0x80CE0000The response is not valid for the dialog
0x80CF0000The condition branch has already been acknowledged
0x80D00000The condition branch has already been confirmed
0x80D10000The condition has already been shelved
0x80D20000The condition is not currently shelved
0x80D30000The shelving time not within an acceptable range
0x809B0000No data exists for the requested time range or event filter
0x80D70000No data found to provide upper or lower bound value
0x80D80000The server cannot retrieve a bound for the variable
0x809D0000Data is missing due to collection started/stopped/lost
0x809E0000Expected data is unavailable for the requested time range due to an un-mounted volume
0x809F0000The data or event was not successfully inserted because a matching entry exists
0x80A00000The data or event was not successfully updated because no matching entry exists
0x80A10000The client requested history using a timestamp format the server does not support (ie requested ServerTimestamp when server only supports SourceTimestamp)
0x00A20000The data or event was successfully inserted into the historical database
0x00A30000The data or event field was successfully replaced in the historical database
0x40A40000The value is derived from multiple values and has less than the required number of Good values
0x00A50000No data exists for the requested time range or event filter
0x00A60000The data or event field was successfully replaced in the historical database
0x80D40000The requested number of Aggregates does not match the requested number of NodeIds
0x80D50000The requested Aggregate is not support by the server
0x80D60000The aggregate value could not be derived due to invalid data inputs
0x80DA0000The aggregate configuration is not valid for specified node
0x00D90000The request specifies fields which are not valid for the EventType or cannot be saved by the historian
0x80E40000The request was rejected by the server because it did not meet the criteria set by the server
0x81130000The request has not been processed by the server yet
0x811F0000The device identity needs a ticket before it can be accepted
0x81200000The device identity needs a ticket before it can be accepted
0x00DC0000The value does not come from the real source and has been edited by the server
0x00DD0000There was an error in execution of these post-actions
0x40DE0000The related EngineeringUnit has been changed but the Variable Value is still provided based on the previous unit
0x00E00000A dependent value has been changed but the change has not been applied to the device
0x80E10000The related EngineeringUnit has been changed but this change has not been applied to the device The Variable Value is still dependent on the previous unit but its status is currently Bad
0x40E20000A dependent value has been changed but the change has not been applied to the device The quality of the dominant variable is uncertain
0x80E30000A dependent value has been changed but the change has not been applied to the device The quality of the dominant variable is Bad
0x01160000It is delivered with a dominant Variable value when a dependent Variable has changed but the change has not been applied
0x01170000It is delivered with a dependent Variable value when a dominant Variable has changed but the change has not been applied
0x01180000It is delivered with a dependent Variable value when a dominant or dependent Variable has changed but change has not been applied
0x81190000It is delivered with a Variable value when Variable has changed but the value is not legal
0x811A0000It is delivered with a Variable value when a source Variable has changed but the value is not legal
0x811B0000It is delivered with a dependent Variable value when a dominant Variable has changed and the value is not legal
0x811C0000It is delivered with a dependent Variable value when a dominant Variable has changed
0x811D0000It is delivered with a dependent Variable value when a dominant or dependent Variable has changed and the value is not legal
0x811E0000It is delivered with a dependent Variable value when a dominant or dependent Variable has changed
0x00A70000The communication layer has raised an event
0x00A80000The system is shutting down
0x00A90000The operation is not finished and needs to be called again
0x00AA0000A non-critical timeout occurred
0x80AB0000One or more arguments are invalid
0x80AC0000Could not establish a network connection to remote server
0x80AD0000The server has disconnected from the client
0x80AE0000The network connection has been closed
0x80AF0000The operation cannot be completed because the object is closed
0x80B00000Cannot move beyond end of the stream
0x80B10000No data is currently available for reading from a non-blocking stream
0x80B20000The asynchronous operation is waiting for a response
0x80B30000The asynchronous operation was abandoned by the caller
0x80B40000The stream did not return all data requested (possibly because it is a non-blocking stream)
0x80B50000Non blocking behaviour is required and the operation would block
0x80B60000A value had an invalid syntax
0x80B70000The operation could not be finished because all available connections are in use