IO619 - Status
IO619 - Status — Reads the device status
information
Library
Simulink Real-Time - Speedgoat

Description
This block provides status information of the specifed device in the corresponding
Setup block.
Ports
Outputs
-
LAT
Line A trusted status flag.
-
RLD
Redundant line disturbed status flag.
-
Line A Error
Counter increments if the device status or process data frame is
received on line B but not on line A.
-
Line B Error
Counter increments if the device status or process data frame is
received on line A but not on line B.
Parameters
-
Module ID
This ID defines the link to the corresponding Setup block
-
Enable Line Errors
Select whether the line error counter output should be
available.
-
Sample Time
Defines the base sample time at which this driver block gets its sample hit. This
parameter can also be set to -1 for inherited
sample time. The units are in seconds.