IO424 Usage Notes
IO424 Usage Notes — Usage information about the
I/O module
Status Error bits description
QUAD: Quadrant-Detection Error. While
at '1', Angle/Stroke and Velocity are not
valid.
LOS: SIN/COS Loss-of-Signal. While at
'1', Angle/Stroke and Velocity are valid, but
may be degraded.
CLIP SIN: SIN Clipping. While at '1',
Angle/Stroke and Velocity are not
valid.
CLIP COS: COS Clipping. While at '1',
Angle/Stroke and Velocity are not
valid.
EXC LOW: Excitation Frequency too low.
EXC HIGH: Excitation Frequency too
high.
AMP OT: Excitation Output
Overtemperature Flag.
Connection methods
This section describes the different connection methods for the IO424.
Resolver, with external or internal
reference.

LVDT/RVDT Differential configuration, with external or
internal reference.

LVDT/RVDT Ratiometric configuration, with external or
internal reference.

Synchro configuration, works only with external
reference.