IO116 - Analog output
IO116 - Analog output —
Writes the IO116 analog outputs
Library
Simulink Real-Time - Speedgoat

Description
Your model can only contain one of these blocks for each I/O module in your target
machine.
Ports
This driver block has n double-type scalar input ports, where n is the number of
selected analog output channels. Each port (signal) accepts the D/A value to be
output in volts or amperes depending on the Enable Current Output parameter in the
Analog Output tab of the Setup block.
Inputs
-
X (X is the D/A channel number)
The value to be output from D/A channel X in volts or amperes
depending on the Enable Current Output parameter in the Analog Output
tab of the Setup block.
Data Type:
double
Parameters
The configuration details are all defined in the Setup block.
-
Module ID
This ID defines the link to the corresponding Setup block
-
Sample Time
Defines the base sample time at which this driver block gets its sample hit. This
parameter can also be set to -1 for inherited
sample time. The units are in seconds.