IO116 - Analog input
IO116 - Analog input —
Reads the IO116 analog inputs
Library
Simulink Real-Time - Speedgoat

Description
Your model can only contain one of these blocks for each I/O module in your target
machine.
Ports
This driver block has n double-type scalar output ports, where n is the number of
selected analog input channels. Each port (signal) returns the analog value in volts
or amperes depending on the Current Transceiver parameter in the Analog Input tab of
the Setup block.
Outputs
-
X (X is the A/D channel number)
The value from A/D channel X in volts or amperes depending on the
Current Transceiver parameter in the Analog Input tab of the Setup
block.
Data Type:
double
Parameters
The configuration details are all defined in the Setup block.
-
Module ID
This ID defines the link to the corresponding Setup block
-
Sample Time
Defines the base sample time at which this driver block gets its sample hit. This
parameter can also be set to -1 for inherited
sample time. The units are in seconds.