IO754 - Send v2
IO754 - Send v2 — Transmits cyclic data to the
Modbus TCP client
Library
Simulink Real-Time - Speedgoat

Description
This block is used to send data to the MODBUS TCP client connected with the IO754
module. Further information about the operation modes is available in the IO754 Usage
Notes.
Your model can contain only one Receive block for each
I/O module in your target machine.
Ports
Inputs
One vector of data type UINT8 which the block writes to the output
data area of the dual-port memory. This area contains data which is sent
to the Modbus TCP client. Use Byte
Packing blocks to assemble the vector from specific data.
The Number of Bytes parameter sets the
length of this vector.
Type:
scalar | vector
Data Type:
uint8
Outputs
This block does not have any output ports.
Parameters
-
Module ID
This ID defines the link to the corresponding Setup block
-
Port Type
Always select 1 port with n element vector of type
uint8
-
Number of Bytes
This parameter defines the length of the input port and thus the number of
bytes to be written to the module's output data area (TX). Refer to the usage
notes to learn how to use this parameter.
-
Sample Time
Defines the base sample time at which this driver block gets its sample hit. This
parameter can also be set to -1 for inherited
sample time. The units are in seconds.
![[Caution]](images/caution.png) | Caution |
|---|
All blocks that interface with the same I/O module must have identical
sample times. |