IO754 - Receive v2
IO754 - Receive v2 — Receives cyclic data from the
Modbus TCP client
Library
Simulink Real-Time - Speedgoat

Description
This block is used to receive data from the MODBUS TCP client connected with the
IO754 module. Further information about the operation modes is available in the
IO754 Usage
Notes.
Your model can contain only one Receive block for each
I/O module in your target machine.
Ports
Outputs
One vector of data type UINT8 which the block reads from the input
data area of the dual-port memory. This area contains data which has
been received from the Modbus TCP client. Use Byte
Unpacking blocks to extract specific data. The Number of Bytes parameter sets the length of
this vector.
Type:
scalar | vector
Data Type:
uint8
Inputs
This block does not have any input ports.
Parameters
-
Module ID
This ID defines the link to the corresponding Setup block
-
Port Type
Always select 1 port with n element vector of type
uint8
-
Number of Bytes
This parameter defines the length of the output port and thus the number of
bytes to be read from the module's input data area (RX). Refer to the usage
notes to learn how to use this parameter.
-
Sample Time
Defines the base sample time at which this driver block gets its sample hit. This
parameter can also be set to -1 for inherited
sample time. The units are in seconds.
![[Caution]](images/caution.png) | Caution |
|---|
All blocks that interface with the same I/O module must have identical
sample times. |