IO750 - SDO Read

IO750 - SDO Read — Reads data from local EtherCAT Service Data Objects

Library

Simulink Real-Time - Speedgoat

Description

This block is used to read the service data objects of the subordinate device. Use the IO750 Setup block to define these objects. On the network side the objects can be read and written by the EtherCAT main device.

Your model can contain only one SDO Read block for each I/O module in your target machine. This single block handles all the model's SDO read accesses to the SDO dictionary of the related module.

Your model must contain one Setup block and one SDO Read block for the SDO communication to function. The SDO Write block is optional.

[Caution]Caution

This block is only supported by MATLAB from R2019b.

Ports

Inputs

This block does not have any input ports.

Outputs

This block has one output port for each SDO defined in the SDO table of the related Setup block with a "read" or "read-write" Access Mode. The port type depends on the Data Type property. The name of the port is composed of the Index, Sub Index and Name properties.

If no SDO has a "read" or "read-write" Access Mode then the block will have no output ports.

Parameters

Module ID

This ID defines the link to the corresponding Setup block

Sample Time

Defines the base sample time at which this driver block gets its sample hit. This parameter can also be set to -1 for inherited sample time. The units are in seconds.

[Caution]Caution

All blocks that interface with the same I/O module must have identical sample times.

Retrieve SDO Configuration

Retrieves the SDO configuration from the related Setup block and updates the output ports.