Documentation search search close
CONTENTS
https://www.speedgoat.com/help/slrt/page/icon_documentation.jpg
v10.0.1.x for R2026a
View other versions

Serial Onboard

Serial Onboard — The Serial Onboard are driver blocks for real-time target machines supporting RS232/422/485 protocols

Serial Interfaces on Real-Time Target Machines

All available real-time target machines have different hardware specifications. The table below lists the currently supported real-time target machines, showing the number of supported serial interfaces, RS422/485 compatibility, and the maximum baud rate for each

Real-Time Target MachineSerial InterfacesSupported Baud Rates
Performance P3 (Item ID: 109301)2x RS232 up to 115.2 kbaud/s (standard baud rates)
Performance (Item ID: 109100)2x RS232 up to 115.2 kbaud/s (standard baud rates)
Pulse

2x RS232/RS422/RS485

RS232: up to 500 kbaud/s (standard or custom baud rates)

RS422/RS485: up to 1Mbaud/s (standard or custom baud rates)

Baseline 2x RS232up to 115.2 kbaud/s (standard baud rates)
Mobile

Default: 4x RS232

Option: 2x RS232 & 2x RS422/RS485

up to 115.2 kbaud/s (standard baud rates)
Unit--
[Note]Note

Mobile: RS422/RS485 is only supported on ports 3 and 4, providing the corresponding hardware option has been ordered for the Mobile real-time target machine (v2)

OnBoard Serial Runtime license

Some functionalities require a runtime license. Refer to the Runtime Licensing page for additional information.

Licensed features for the Pulse real-time target machine are as follows:

  • RS422/RS485

  • Custom baud rates in the declared range. Without a license, only a list of standard baud rates in the declared range is available.