IO752 - Send

IO752 - Send — Transmits cyclic data from the Controller to the PROFINET network

Library

Simulink Real-Time - Speedgoat

Description

This block is used to transmit cyclic data from the Controller to the PROFINET network.

You can only use one PROFINET Device Send block for each physical module installed.

Ports

Depending on the value of the "Port type" parameter, this block will have:

  • n input ports of type uint8, where n is defined by the "Output Data Bytes" parameter, or

  • 1 input port which is a vector with n elements, where n is defined by the "Output Data Bytes" parameter.

Inputs (n ports of type uint8)
1

Data byte to send. Type uint8.

X (X is the port number, between 1 and the value of the "Output Data Bytes" parameter)

Data byte to send. Type uint8.

Inputs (1 port with n vector elements)
Out

A vector of data bytes to send. The number of elements in the vector is defined by the "Output Data Bytes" parameter.

Parameters

Module ID

This ID defines the link to the corresponding Setup block.

Port type

The type of the input ports. Options are:

  • n ports of type UINT8 to have an input port for each signal.

  • 1 port with n element vector of type UINT8 to have a single vector with an element for each signal.

Output data bytes

The number of bytes that are sent to the PROFINET device. TIP: Use the "Byte Pack" block to send the data.

Sample time [s]

Defines how often this block is updated.