Description

Your model can contain only one Setup block for each I/O module in your target machine.

All the supported I/O types for this module can be configured in the Setup block dialog box. This block will therefore have an impact on all the other driver blocks (Send, Receive, Update Scheduled Messages).

Ports

This driver block has no input or output ports.

Parameters

The three tabs of the setup parameter dialog box contain the IO682 I/O module configuration settings.

Main Tab
IO682 Variant

The IO682 I/O module is available in different variants which differ in terms of the number of receive and transmit channels. Select the variant that has been installed in your target machine.

PCI Slot (-1: auto-search)

There are two approaches for mapping this block to a specific I/O module installed in your target machine. All modules of the same type must be configured using the same method.

  • Auto-Search: with the default value -1 the I/O module will be automatically located in the target machine. If you have multiple modules of the same kind, the Module ID defines which module is associated with this block. To see how each I/O module maps to a Module ID, use this Speedgoat API:

    speedgoat.getIoInterfaces("TargetName", "mySpeedgoat")

  • Explicit Addressing: to explicitly define the logical address of the I/O module in the target machine, you can provide the PCI bus and slot numbers as a vector: [bus, slot]. To determine these numbers, run the following command in the MATLAB command window:

    speedgoat.getIoInterfaces("TargetName", "mySpeedgoat", "Advanced", true)

    Note that the PCI address can change whenever an I/O module is added or removed – usually, auto-search is the best option.

Timer Tick Length (in 0.25 us steps)

Specify the length of a timer tick in 0.25 µs units. The default value is 4000, which results in a tick length of one millisecond. If you select time tags from an ARINC Decode or Receive block, then the time tags are provided in units of timer ticks.

Channel Configuration Tab
Mode

Select whether the channels should be configured manually or by a configuration file.

Bit Rate

Specify the receive bus speed in Hertz. Typical ARINC 429 rates are 12.5 kHz and 100 kHz. The valid range is from 200 Hz to 150 kHz.

Buffer Mode

Select the receive buffer mode, which can be individual or merged. In the individual mode, each receiver can store up to 2,048 messages in its circular buffer. Multiple channels can be configured to use the merged mode, where the received messages are buffered in a single circular buffer. This buffer can store up to 16,384 messages, which can be accessed through channel 1.

Enable

Check this box to enable the receiver.

Parity Check

Check this box to enable the parity check when receiving messages. When enabled, bit 31 in the ARINC 429 message will indicate whether the parity check was successful (0) or failed (1).

Internal Wrap

Check this box to enable the internal wrap of the receive buffer. When enabled, the transmitter is internally connected to the respective receive channel (internal loopback).

Bit Rate

Specify the transmit bus speed in Hertz. Typical ARINC 429 rates are 12.5 kHz and 100 kHz. The valid range is from 200 Hz to 150 kHz.

Parity

Select the type of parity which will be assigned to each transmitted ARINC 429 message. The available values are Odd, Even and None. If None is selected, the parity bit can be manually controlled by using the RAW data type in the Encode block.

Protocol Error

Select None, Bit Count High, Bit Count Low or Short Gap for the type of error injection transmitted on this channel.

None will transmit the messages normally, Bit Count High will result in messages with a bit count of 33 bits, Bit Count Low will result in messages with a bit count of 31 bits and Short Gap will result in the insertion of only 3 bits between subsequent messages.

Enable

Check this box to enable the transmitter.

Channels Configuration File

Specify the name of the configuration file. Click the Browse button to easily find your file or enter it manually. By clicking the Refresh Data button, the whole configuration file is parsed again. The channel configuration can be saved by clicking the Save Configuration button when using the manual configuration mode. The generated file can be used as well to configure other modules.

Scheduled Messages Tab
Mode

Select whether the scheduled messages should be configured manually or by a configuration file.

Scheduled Messages Configuration File

Specify the name of the configuration file. Click the Browse button to easily find your file or enter it manually. By clicking the Refresh Data button, the whole configuration file is parsed again. The scheduled message list can be saved by clicking the Save Configuration button when using the manual configuration mode. The generated file can be used as well to configure other modules. To manually create a scheduled message list click the Create Message List button.