Analog IO337-650k - Analog Output v1
Analog IO337-650k - Analog Output v1 — This driver block is
available for the IO337-650k.
Library
Simulink Real-Time - Speedgoat

Description
The number of Analog output v1 blocks in your model must match the number of
IO337-650k I/O modules installed in your target machine.
Ports
This driver block has n scalar input ports of type double or single, where n is
the number of analog output channels selected. Each port (signal) accepts the analog
value in volts to be output.
Inputs
-
X (X is the analog channel number)
The value to be output from analog channel X in volts. The data type
is double or single.
![[Note]](images/note.png) | Note |
|---|
The IO337 Analog output block supports single- or double-precision data types
as inputs (all inputs must be of the same type). While double-precision data
types offer better accuracy, single-precision data types can decrease
task-execution time. |
Parameters
The configuration details are all defined in the IO337-650k Analog Setup v1
block.
-
Configurable I/O Module ID
This parameter associates a code module block with a configurable I/O module setup
block. Set this value to match the Module ID defined in the setup block of the
required configurable I/O module.
-
Sample Time
Defines the base sample time at which this driver block gets its sample hit. This
parameter can also be set to -1 for inherited
sample time. The units are in seconds.