Analog IO324-200k - Analog Input v1
Analog IO324-200k - Analog Input v1 — This driver block is available for the
IO324-200k.
Library
Simulink Real-Time - Speedgoat

Description
Your model can only contain one of these blocks for each I/O module in your target
machine.
Ports
This driver block has n scalar output ports of type double where n is the number
of selected analog input channels. Each port (signal) returns the converted analog
values in Volts.
Outputs
-
X (X is the analog channel number)
The value from analog channel X in Volts. Type double.
Parameters
The configuration details are all defined in the IO324-200k Analog Setup v1
block.
-
Configurable I/O Module ID
This parameter associates a code module block with a configurable I/O module setup
block. Set this value to match the Module ID defined in the setup block of the
required configurable I/O module.
-
Sample Time
Defines the base sample time at which this driver block gets its sample hit. This
parameter can also be set to -1 for inherited
sample time. The units are in seconds.