IO102 - Analog Input
IO102 - Analog Input — Reads the IO102 analog
inputs
Library
Simulink Real-Time - Speedgoat

Description
Your model can only contain one of these blocks for each I/O module in your target
machine.
Ports
This driver block has n double-type scalar output ports, where n is the number of
selected analog input channels. Each port (signal) returns the analog value in
volts.
Outputs
-
X (X is the analog channel number)
The value from analog channel X in volts.
Data Type:
double
Parameters
-
Module ID
This ID defines the link to the corresponding Setup block
-
High-Voltage Ordering Option
This check box should be ticked if the IO102 I/O module installed in
your target machine is the high voltage option (part number IO102-HV).
The standard option has analog input ranges of ±10 V, ±5 V and
±2.5 V. The high voltage option has analog input ranges of
±60 V, ±30 V, and ±15 V for channels 17 to 32 (in
Single-Ended mode) and channels 9 to 16 (in Differential mode). The
other channels remain standard. For the high voltage channels, when
selecting ±10 V (LV), ± 60 V (HV) is set as the HV input range. The
ranges ±30 V and ±15 V are mapped to ±5 V and ±2.5 V
respectively.
-
Sample Time
Defines the base sample time at which this driver block gets its sample hit. This
parameter can also be set to -1 for inherited
sample time. The units are in seconds.