Documentation search search close
CONTENTS
https://www.speedgoat.com/help/slrt/page/icon_documentation.jpg
v10.0.1.x for R2026a
View other versions

IO206 - Setup

IO206 - Setup — Configure the IO206 read block

Library

Simulink Real-Time - Speedgoat

Description

Your model can contain only one Setup block for each I/O module in your target machine.

Ports

This driver block has no input or output ports.

Parameters

Parameter Group

This control selects an I/O section, the parameters of which are then shown in the dialog box below the 'Parameter Group' field. Possible groups are:

  • Module setup

  • Digital input setup

Parameter Group: Module setup
Module ID

The Module ID has two functions:

  • It defines the logical connection between the Setup block and its I/O blocks

  • It also informs the auto-search feature of the PCI Slot parameter. If only one I/O module of this type is installed, the Module ID must be set to 1. If n modules are installed, it must be in the range 1:n. Not all the I/O modules installed in the target machine need to be used. To see how each I/O module maps to a Module ID, use this Speedgoat API:

    speedgoat.getIoInterfaces("TargetName", "mySpeedgoat")
PCI Slot (-1: auto-search)

There are two approaches for mapping this block to a specific I/O module installed in your target machine. All modules of the same type must be configured using the same method.

  • Auto-Search: with the default value -1 the I/O module will be automatically located in the target machine. If you have multiple modules of the same kind, the Module ID defines which module is associated with this block. To see how each I/O module maps to a Module ID, use this Speedgoat API:

    speedgoat.getIoInterfaces("TargetName", "mySpeedgoat")

  • Explicit Addressing: to explicitly define the logical address of the I/O module in the target machine, you can provide the PCI bus and slot numbers as a vector: [bus, slot]. To determine these numbers, run the following command in the MATLAB command window:

    speedgoat.getIoInterfaces("TargetName", "mySpeedgoat", "Advanced", true)

    Note that the PCI address can change whenever an I/O module is added or removed – usually, auto-search is the best option.

Parameter Group: Digital input setup
Enable Debounce

This setting applies to all 32 input channels. If unchecked inputs are not debounced. If checked the inputs are debounced based on the 'Debounce Time' setting below.

Debounce Time

This setting applies to all 32 input channels. If the 'Enable Debounce' dialog field (see above) is checked then input changes faster than the time specified here will be ignored. The debounce time is the same for all input channels and can be specified in seconds in the range of 7e-6 s (7 µs) and 0.440 s (440 ms) in steps of approximately 7 µs.