IO113 - Setup

IO113 - Setup — Configure the IO113 input/output blocks

Library

Simulink Real-Time - Speedgoat

Description

Your model can contain only one Setup block for each I/O module in your target machine.

The Setup block dialog box allows all the supported I/O types of this module to be configured and therefore impacts on the other driver blocks (Analog output, Digital output, Digital input).

Ports

This driver block has no input or output ports.

Parameters

Parameter Group

This control selects an I/O section, the parameters of which are then shown in the dialog box below the 'Parameter group' field. Possible groups are:

  • Module setup

  • Analog output setup

  • Digital I/O setup

Parameter Group: Module setup
Module ID

The Module ID has two functions:

  • It defines the logical connection between the Setup block and its I/O blocks

  • It also informs the auto-search feature of the PCI Slot parameter. If only one I/O module of this type is installed, the Module ID must be set to 1. If n modules are installed, it must be in the range 1:n. Not all the I/O modules installed in the target machine need to be used. To see how each I/O module maps to a Module ID, use this Speedgoat API:

    speedgoat.getIoInterfaces("TargetName", "mySpeedgoat")
Autocalibration

Check this box if the module should calibrate itself the next time this model (target application) is downloaded and initialized. The autocalibration function compensates for component aging and minimizes the effects of temperature on accuracy. We recommend keeping this enabled. The calibration normally takes approximately 2 seconds, so we suggest increasing the host-target communication time-out in the model configuration parameters to allow for this. The status of the calibration is displayed on the target screen. The calibration is not re-executed during normal start/stop operation once the target application has been downloaded. Warning: During the calibration process various signals may be present at the output pins, but they will stay inside the configured voltage range.

PCI Slot (-1: auto-search)

There are two approaches for mapping this block to a specific I/O module installed in your target machine. All modules of the same type must be configured using the same method.

  • Auto-Search: with the default value -1 the I/O module will be automatically located in the target machine. If you have multiple modules of the same kind, the Module ID defines which module is associated with this block. To see how each I/O module maps to a Module ID, use this Speedgoat API:

    speedgoat.getIoInterfaces("TargetName", "mySpeedgoat")

  • Explicit Addressing: to explicitly define the logical address of the I/O module in the target machine, you can provide the PCI bus and slot numbers as a vector: [bus, slot]. To determine these numbers, run the following command in the MATLAB command window:

    speedgoat.getIoInterfaces("TargetName", "mySpeedgoat", "Advanced", true)

    Note that the PCI address can change whenever an I/O module is added or removed – usually, auto-search is the best option.

Parameter Group: Analog output setup
Output Range

Select one of the three available analog output ranges. The selected range applies to all analog channels.

Mode

Select either Single-ended or Differential. For more information please see the I/O pin mapping section and the technical reference manual of the I/O module. For Single-ended channels each output signal is referenced between the HI line and the Output return (GND). For Differential channels the voltage is referenced between the HI line and LO line.

Active Channels

Select the active input/output channels in a vector. A defined number of channels can be selected using square brackets, for example [1 2 3]. A sequence of channels can be selected using a colon, for example, 1:4.

Initial Values

Define the initial signal level present on the outputs after the application has been downloaded. The values can be set individually by entering a vector: the value at a certain position in the Initial Values vector is applied to the channel as defined in the Active Channels vector. A scalar value applies to all the channels; for example, for individual values, type "[1 1.5 0 2.5]", and to set all channels to zero, type "0".

Reset to Initial Values

Define whether the initial values are also applied once the application has stopped. The behavior can be set individually for each channel using a vector. A scalar value applies to all the channels; for example, for individual values, type "[1 0 0 1]", and to set all channels to zero, type "0". "1" means use the Initial Value and "0" means keep the latest value.

Parameter group: Digital I/O setup
Direction of Channels 1-4

The direction (Input or Output) for channels 1 to 4

Direction of Channels 5-8

The direction (Input or Output) for channels 5 to 8

Initial Values

Define the initial signal level present on the outputs after the application has been downloaded. The values can be set individually by entering a vector: the value at a certain position in the Initial Values vector is applied to the channel as defined in the enabled channels. A scalar value applies to all the channels; for example, for individual values, type "[1 0 0 1]", and to set all channels to zero, type "0".

Reset to Initial Values

Define whether the initial values are also applied once the application has stopped. The behavior can be set individually for each channel using a vector. A scalar value applies to all the channels; for example, for individual values, type "[1 0 0 1]", and to set all channels to zero, type "0". "1" means use the Initial Value and "0" means keep the latest value.