IO107 - Analog output
IO107 - Analog output —
Writes the IO107 analog outputs
Library
Simulink Real-Time - Speedgoat

Description
To write to the analog outputs exactly one of these blocks must be added to your
model for each module of this type in your target machine.
Ports
This driver block has n double-type scalar input ports, where n is the number of
selected analog output channels. Each port (signal) accepts the analog value in volts to
be output.
Inputs
-
X (X is the analog channel number)
The value to be output from analog channel X in volts.
Data Type:
double
Parameters
The configuration details are all defined in the setup block.
-
Module ID
This ID defines the link to the corresponding Setup block
-
Sample Time
Defines the base sample time at which this driver block gets its sample hit. This
parameter can also be set to -1 for inherited
sample time. The units are in seconds.