Analog: -120 Analog Setup v1 — This driver block is available for the -120 I/O interface extension

Library

Simulink Real-Time - Speedgoat

Description

The number of-120 Analog setup v1 blocks in your model must match the number of configurable I/O modules which are connected to a -120 I/O interface extension and are installed in your target machine.

Use the -120 Analog setup block to define the parameters for all -120 I/O interface extensions connected to a given configurable I/O module. The block will be linked to the IO3xx Setup block with the same Module ID as the -120 Analog Setup block itself.

The block mask will dynamically change based on the configuration file and the I/O interface extensions selected in the IO3xx Setup block.

Ports

This driver block has no input or output ports.

Parameters

Main Tab
Configurable I/O Module ID

This parameter associates a code module block with a configurable I/O module setup block. Set this value to match the Module ID defined in the setup block of the required configurable I/O module.

Code Module Functionality

This box is only visible if your configuration file contains a code module that is using the analog inputs/outputs. If you want to use one of these analog code modules, you need to select the corresponding checkbox. The Analog setup block will then be automatically configured to support this analog code module. Parameters needing to be set to a specific value will be grayed out.

Analog input and output channels not reserved by an analog code module can still be used, but the channel group will be triggered by the code module. When the DMA interrupt is enabled, the whole channel group will be automatically disabled.

Analog Input Trigger - Enable Individual Trigger Settings

This checkbox selects between individual trigger settings per channel group or common trigger settings, which apply for all channels.

Trigger Settings - ADC Sample Trigger

The block supports up to four trigger options for the analog inputs depending on the settings of Enable Individual Trigger Settings and Enable DMA Interrupt

  • Model Step At each model sample step the analog input channels are triggered and the driver actively waits until the analog data is converted and read back. The task execution time will depend on the number of analog input channels selected. This option is only available when Enable DMA Interrupt is not selected.

  • I/O Module Clock The triggering of the analog channels is based on the internal clocking functionality. The ADC Sample Rate can be configured to the desired rate.

  • I/O Module Internal Signal The triggering of the analog channels is based on I/O module internal signals. The available signals depend on what is supported in the corresponding configuration file.

  • I/O Module Digital I/O The triggering of the analog channels is based on a configurable digital I/O pin. Both input and output signals can be used for triggering.

Read Value From Previous Model Step

At each model sample step the analog input data from the previous time step is read and new conversions of the enabled analog input channels are triggered, which will be read in the next model execution. This mode avoids the active wait time of the analog conversion and therefore has a lower task execution time.

ADC Sample Rate [Hz]

This parameter is used to configure the internal sampling clock of the ADC.

Internal Signal

This parameter is available if ADC Sample Trigger is set to I/O Module Internal Signal. A list of available internal trigger signals is shown in the drop-down menu. If no signal is available, then the selected configuration file does not include internal trigger signals; in this case choose a different trigger option.

Digital I/O Channel

This parameter is available if ADC Sample Trigger is set to I/O Module Digital I/O. Specify the digital I/O channel number to configure the corresponding signal as trigger signal. If the selected I/O line is configured as digital input in your model, an external signal can be connected for triggering. But the trigger signal routing also works for output signals and as well for code module functionality. For example if a digital line is configured as PWM-Trigger output signal, then the signal is also internally routed to the trigger input of the analog channels and can be used for triggering.

Oversampling Factor

Select the oversampling configuration: none, 2, 4, 8, 16, 32 or 64. If oversampling is active, the I/O module takes the selected number of samples and averages them to one sample. In Frame-Based mode, only every nth sample is transferred over DMA. In Sample-Based mode, the filter acts as a moving average, and the CPU reads out the latest value.

Enable DMA Interrupt

The analog input data read back is organized in frames and can be synchronized using an interrupt. Either a triggered subsystem or the whole model can be executed based on the DMA interrupt. This checkbox is only visible, when Enable Individual Trigger Settings is disabled.

Frame-Based Settings - Trigger Resolution [s]

This parameter is shown if Enable DMA Interrupt is checked. The parameter is disabled and cannot be changed and only shows the applicable time resolution of the ADC trigger signal. The ADC sample time will be rounded to an integer multiple of the Trigger Resolution.

Frame-Based Settings - ADC Sample Rate [Hz]

This parameter is available if Enable DMA Interrupt is checked. The ADC Sample Rate is used to configure the internal sampling clock, if Sample Trigger is set to I/O Module Clock. For the other ADC Trigger Settings it is used to calculate the expected block sample time.

Frame-Based Settings - Frame Size (samples/channel)

This parameter is available if Enable DMA Interrupt is checked.

Select how many samples are transferred from the module at each CPU model step. The block port signal of every channel becomes a vector with the same number of values, where the value at position 1 is taken first. Enter "-1" to allow the system to determine the frame size automatically based on the ADC Sample Rate and the Input Block Sample Time.

Frame-Based Settings - Input Block Sample Time [s]

This parameter is available if Enable DMA Interrupt is checked.

Define the base sample time at which the Analog input interrupt gets asserted. Enter "-1" to allow the system to determine the block sample time automatically based on the ADC Sample Rate and Frame Size.

[Note]Note

One of the three Frame-Based Settings must be configured automatically (-1). The exact settings used to configure the ADC will be calculated based on the Trigger Resolution and are shown next to the parameters

Analog Output Trigger - DAC Sample Trigger

The block supports four trigger options for the analog outputs:

  • Model Step At each model sample step, the analog values are written to the I/O module and the analog output channels get updated.

  • I/O Module Clock The triggering of the analog channels is based on the internal clocking functionality. If Enable DMA Interrupt is checked, then the DAC Sample Rate can be configured; otherwise the DAC Sample Rate is set to the maximum achievable rate.

  • I/O Module Internal Signal The triggering of the analog channels is based on I/O module internal signals. The available signals depend on what is supported in the corresponding configuration file.

  • I/O Module Digital I/O The triggering of the analog channels is based on a configurable digital I/O pin. Both input and output signals can be used for triggering.

Internal Signal

This parameter is available if DAC Sample Trigger is set to I/O Module Internal Signal. A list of available internal trigger signals is shown in the drop-down menu. If no signal is available, then the selected configuration file does not include internal trigger signals; in this case choose a different trigger option.

Digital I/O Channel

This parameter is available if DAC Sample Trigger is set to I/O Module Digital I/O. Specify the digital I/O channel number to configure the corresponding signal as a trigger signal. If the selected I/O line is configured as a digital input in your model, an external signal can be connected for triggering. But the trigger signal routing also works for output signals and also for code module functionality. For example, if a digital line is configured as a PWM-Trigger output signal, then the signal is also internally routed to the trigger input of the analog channels and can be used for triggering.

Analog Output Trigger - Enable DMA Interrupt

The analog output data is written to the I/O module and synchronized using an interrupt to ensure continuous data. Either a triggered subsystem or the whole model can be executed based on the DMA interrupt.

Frame-Based Settings - FIFO Threshold

This parameter is available if Enable DMA Interrupt is checked. The FIFO Threshold determines when the interrupt is asserted to request new data from the CPU; this means that the interrupt is asserted as soon as only FIFO Threshold samples/channel remain. The threshold should be chosen such that enough samples are still in the FIFO to output on the DAC, while new data is requested and received from the CPU (this includes: trigger interrupt time, execution of CPU model step, DMA data transfer). The FIFO Threshold value must be equal to or less than the Frame Size value.

Frame-Based Settings - Trigger Resolution [s]

This parameter is shown if Enable DMA Interrupt is checked. The parameter is disabled and cannot be changed and only shows the applicable time resolution of the DAC trigger signal. The DAC sample time will be rounded to an integer multiple of the trigger resolution.

Frame-Based Settings - DAC Sample Rate [Hz]

This parameter is available if Enable DMA Interrupt is checked. The DAC Sample Rate is used to configure the internal sampling clock, if Sample Trigger is set to I/O Module Clock; otherwise it is used to calculate the expected block sample time.

Frame-Based Settings - Frame Size (samples/channel)

This parameter is available if Enable DMA Interrupt is checked.

Select how many samples are transferred to the module at each sample hit. The block port signal of every channel becomes a vector with the same number of values, where the value at position 1 is taken first. Enter "-1" to allow the system to determine the frame size automatically based on the DAC Sample Rate and Frame Size.

Frame-Based Settings - Output Block Sample Time [s]

This parameter is available if Enable DMA Interrupt is checked.

Define the base sample time at which the Analog output interrupt gets asserted. Enter "-1" to allow the system to determine the block sample time automatically based on the DAC Sample Rate and Frame Size.

[Note]Note

One of the three Frame-Based Settings must be configured automatically (-1). The exact settings used to configure the DAC will be calculated based on the Trigger Resolution and are shown next to the parameters

Analog Inputs Tab

The number of tabs displayed depends on the -120 I/O interface extensions selected in the IO3xx Setup block. For each -120 extension enabled, one tab is generated (Analog Inputs Position x) containing the corresponding analog input channels for the specific physical position in question.

The settings of the analog input channels on these tabs are organized into two groups, corresponding to the two physical ADC chips on the -120. The voltage range of all the channels is fixed to ±20 V.

Analog Inputs Position x

Choose the active analog input channels by selecting the corresponding checkboxes.

Analog Outputs Tab

The number of tabs displayed depends on the -120 I/O interface extensions selected in the IO3xx Setup block. For each -120 extension enabled, one tab is generated (Analog Outputs Position x), containing the corresponding analog output channels for the specific physical position in question.

Available Channels

Choose the active output channels by selecting the corresponding checkboxes. A separate row for the channel settings is displayed for each active channel. The corresponding channels will be automatically enabled for all the code module functionalities activated

Common Output Voltage Range

Select the output voltage range for all the channels of this -120: ±2.5 V, ±5 V, ±10 V,

Initial Value [V]

Define the initial signal level present on the specific output after the application has been downloaded. The values can be set individually by entering the initial value for each channel according to the output range selected.

Reset to Initial Value

Define whether the initial value is also applied once the application has stopped. The behavior can be set individually for each channel by selecting the checkbox.