OPC UA Security
In this example, one OPC UA Client communicates with two OPC UA Servers. All three OPC UA stations are in the same system and on the same Ethernet interface. This is achieved by assigning multiple IP addresses to one Ethernet interface. With this setup, the OPC UA Client and Servers are on the same physical Ethernet interface. Both servers provide data that the client can read and write.
Setup
Prerequisites
You will require the following to run this example:
- Speedgoat real-time target machine with at least one unused Ethernet interface
- "Runtime License File" that includes one OPC UA Client license and two OPC UA Server licenses. Refer to the Runtime Licensing documentation for more information
The OPCUA_Cert.zip package includes the certificate and private key files required by the example. Unzip the file into the same directory which contains the model file.
% Unpack the certificates
Certificate verification requires a valid system time.
Wiring of Target Machine
No physical wiring is required.
Ethernet Configuration of the Client and Servers
Use the Speedgoat Ethernet Configuration Tool to assign the IP address to one unused Ethernet interface (on-board or IO71x/IO79x) on the target machine. Communication between the client and the server(s) on the unused Ethernet interface is performed over the localhost. No cable is required.
The IP address assigned should be 192.168.10.1. The netmask for this local address is 255.255.255.0. This IP is used as the gateway address for the client and server(s) in this example.
% Configure the Ethernet interface for the OPC UA example
speedgoat.configureEthernet; % Open the Speedgoat Ethernet Configuration tool
Add the IP addresses of the client and server(s) to the same Ethernet interface. Adapt the name of the interface according to your target machine configuration.
IP_Client_10 = '192.168.10.10';
IP_Server_20 = '192.168.10.20';
IP_Server_21 = '192.168.10.21';
InterfaceName = 'ETH1'; % Ethernet Interface on the target machine used for this example. Adapt this according to your machine.
ipAliasObj = speedgoat.IpAliasConfiguration();
ipAliasObj.add(InterfaceName, {IP_Client_10, IP_Server_20, IP_Server_21});
Check the server Ethernet settings:
Initialize and Open the Simulink Model
modelName = 'sgMdl_OPCUA_Security';
Model Description
The model sets up the communication for the OPC UA Client and the OPC UA Servers. The Station ID, Connection ID and IP address parameters are aligned to achieve a better understanding of signal flow and how the blocks are related. The first server has Station ID 20 and its IP address ends with 20. The client communicates with the server via Connection ID 20. The second server has Station ID 21 and its IP address ends with 21. The client communicates with the server via Connection ID 21. The client has Station ID 10 and its IP address ends with 10. Station ID and Connection ID parameters are not related to the OPC UA protocol. Instead, they just serve to link blocks in the Simulink model.
In addition to the endpoint with security policy None, both servers provide 2 secure endpoints. The first endpoint is used for message encryption and is different for both servers (Basic128Rsa15 and Basic256Sha256). The matching security policies and modes are selected in the corresponding connection blocks on the client side. The last endpoint in the endpoints' list of both servers determines the security policy for username and password encryption (Aes128_Sha256_RsaOaep in both cases). Signing and encryption with OPC UA requires public X509 certificates and private keys for each participant. The files are included in the example and linked with the respective Client Connection and Server Setup blocks. The first server has no certificate Trust List defined; therefore it accepts all client certificates. The second server refers to a Trust List that contains the client's certificate only. This server will only allow connection with the client simulated in the model. Connection attempts by external clients will be rejected. You can use an external client tool to connect to the servers in parallel, view the tree and monitor the signals. The UA Expert is a common tool for that purpose. As for user authentication, both servers allow the following users to connect:
- User 1 with username "user1" and password "password1"
- User 2 with username "user2" and password "password2"
User authentication is configured with the Usernames and Passwords parameters of the Server Setup blocks. Build, Download, and Run the Example
To run the example, either run the following code section or click the Run on Target button in the REAL-TIME tab in the Simulink model.
% Build the Simulink model
slbuild(modelName); % this will create the real-time application file (.mldatx)
% Create and connect to the Speedgoat real-time target machine
% Download the real-time application to the target machine
tg.setStopTime(30); % seconds
% Prepare the Simulink Data Inspector to plot signals
Simulink.sdi.clearAllSubPlots;
Simulink.sdi.setSubPlotLayout(1,1);
% Start the real-time application
% Select the signals for plotting, set the axis limits and line colors
sdiRunIDs = Simulink.sdi.getAllRunIDs;
sdiLatestRun = Simulink.sdi.Run.getLatest;
sdiSignals = sdiLatestRun.getAllSignals;
for k = 1:8 % Display all signals in the plot
sdiSignals(k).Checked = 1;
Simulink.sdi.setSubplotLimits(1,1,'AllRange',[0,30,-140,140]);
The output is then visible in the Simulink Data Inspector (SDI). You should see the four signals the first server receives from the client and the four signals the client receives from the second server.
Restore Target Machine Configuration
To restore the default configuration, you can simply reopen the Speedgoat Ethernet Configuration Tool and tick the Show Advanced Settings checkbox. Then click the Restore button in the bottom right.
This will erase the IPs of every Ethernet interface and set the host link IP to 192.168.7.5 and the netmask to 255.255.255.0.
We recommend restoring the default settings to reduce possible configuration errors.
Additional References