IO132 - Analog and Digital Loopback
This example demonstrates a simple communication between the two Analog inputs and outputs present on the IO132 I/O module, without using DMA (Direct Memory Access), as well as the communication between two DIO pins.
The IO132 is a fast, simultaneous-sampling, 16-bit analog input and output module, complete with dedicated Simulink® driver blocks.
Setup
Prerequisites
You will require the following to run this example:
- Speedgoat real-time target machine with one IO132 I/O module installed
- Connector cable from the I/O module to the terminal board
- 68-pin terminal board with jumper wires
Test Setup
On the terminal board of the analog I/O module, connect the positive (+) pins of Analog Inputs 1 and 2 to the pins of Analog Outputs 1 and 2, and connect the negative (-) pins of Analog Inputs 1 and 2 to GND. Finally, connect DIO 1 and DIO 5.
Initialize and Open the Simulink model
modelName = 'sgMdl_IO132_Loopback';
Model Description
Build, Download, and Run the Example
To run the example, either run the following code section or click the Run on Target button in the REAL-TIME tab in the Simulink model.
% Build the Simulink model
slbuild(modelName); % this will create the real-time application file (.mldatx)
% Create and connect to the Speedgoat real-time target machine
% Download and install the real-time application on the target machine
% Connect the Simulink model with external mode to the real-time application on the target machine
set_param(modelName,'SimulationMode', 'external') % put model into External Mode
set_param(modelName,'SimulationCommand','connect') % connect with External Mode
% Start the real-time application
% The real-time application on the target machine will automatically stop after 10 seconds
Check the Results
By clicking on the scopes after the model has terminated, you should be able to see the input signal of both channels.
If you wish to sample a signal with a sample rate higher than the fundamental sample time of the Simulink model, consider using DMA. Refer to the other examples for the IO132 I/O module on how to configure DMA.
Additional References