IO130 - DMA Loopback

This example demonstrates how the first two inputs and outputs present on the IO130 I/O module communicate using DMA (Direct Memory Access). The model is triggered by the IO130's DMA interrupt.
The IO130 is a fast, simultaneous-sampling, 16-bit analog input and output module, complete with dedicated Simulink® driver blocks.

Setup

Prerequisites

You will require the following to run this example:
  • Speedgoat real-time target machine with one IO130 I/O module installed
  • Connector cable from the I/O module to the terminal board
  • 50-pin terminal board with jumper wires

Test Setup

On the terminal board of the analog I/O module, connect the positive (+) pins of Analog Inputs 1 and 2 to the pins of Analog Outputs 1 and 2, and connect the negative (-) pins of Analog Inputs 1 and 2 to GND.
IO130_AnalogLoopback_pinWiring.png

Initialize and Open the Simulink model

% Open Simulink model
modelName = 'sgMdl_IO130_DMALoopback';
open_system(modelName);

Model Description

The Simulink model features the IO130 Setup, IO130 Analog Input and IO130 Analog Output blocks. Analog Inputs and Outputs 1 and 2 are enabled in the Setup block.
Furthermore, the model features a Speedgoat Interrupt Setup block, configured as model trigger. If you wish to reuse the example in a larger Simulink model, consider putting the blocks into a Function-Call Subsystem and configuring the Interrupt Setup block accordingly.

Build, Download, and Run the Example

To run the example, either run the following code section or click the Run on Target button in the REAL-TIME tab in the Simulink model.
% Build the Simulink model
slbuild(modelName); % this will create the real-time application file (.mldatx)
 
% Create and connect to the Speedgoat real-time target machine
tg = slrealtime;
tg.connect;
 
% Download and install the real-time application on the target machine
tg.load(modelName);
 
% Connect the Simulink model with external mode to the real-time application on the target machine
set_param(modelName,'SimulationMode', 'external') % put model into External Mode
set_param(modelName,'SimulationCommand','connect') % connect with External Mode
 
% Start the real-time application
tg.start;
 
% Wait a few seconds and then stop the real-time application on the target machine
pause(10)
tg.stop;

Check the Results

By clicking on the scope after the model run has terminated, you should be able to see the input signals.
IO130_DMA_Loopback.PNG
If you zoom in horizontally, you can see the increased sample rate thanks to the active DMA on the module.
Ensure that in the scope, under View > Configuration Properties > Main, the Input Processing option is set to Columns as channels (frame based).
IO130_DMA_Loopback2.PNG