IO117 - Analog Input Test
This example demonstrates a simple communication between an external signal and 2 Analog inputs present on the IO117.
The IO117 I/O module is a high-impedance, sequential-sampling, 16-bit analog input module, complete with dedicated Simulink® driver blocks.
Setup
Prerequisites
You will require the following to run this example:
- Speedgoat real-time target machine with one IO117 I/O module installed
- Connector cable from the I/O module to the terminal board
- 1 50-pin terminal boards with jumper wires
- An external Signal source
Test Setup
On the terminal boards of the analog I/O module, connect the positive (+) pins of the Analog Input 1 and 2 to an external signal and the negative (-) pins of the Analog Input 1 and 2 both to GND of the external signal. Alternatively, you can also use a differential external signal. In that case, connect the negative (-) output of the external signal source to the negative pins of Analog input 1 and 2.
Initialize and Open the Simulink model
modelName = 'sgMdl_IO117_AnalogInputTest';
Model Description
The Simulink model features the IO117 Setup and Analog Input blocks. Analog Input 1 and 2 are enabled in the Setup Block.
Build, Download, and Run the Example
To run the example, either run the following code section or click the Run on Target button in the REAL-TIME tab in the Simulink model.
% Build the Simulink model
slbuild(modelName); % this will create the real-time application file (.mldatx)
% Create and connect to the Speedgoat real-time target machine
% Download and install the real-time application on the target machine
% Connect the Simulink model with external mode to the real-time application on the target machine
set_param(modelName,'SimulationMode', 'external') % put model into External Mode
set_param(modelName,'SimulationCommand','connect') % connect with External Mode
% Start the real-time application
% Wait a few seconds and then stop the real-time application on the target machine
Check the Results
Open the Simulink scope connected to the IO117 Analog input block and check if the signals displayed correspond to the signals created by the external signal generator. Two signals must be displayed. The screenshot below is an example of two 10V sine wave signals with different phase shifts.
Additional References